Adjustment Of The Atdc Sensor - Minolta EPI 054 User Manual

Table of Contents

Advertisement

FrameMaker Ver.5.5(PC) EP1054/EP1085/EP2030 DIS/REASSEMBLY, ADJUSTMENT
98.04.13

(4) Adjustment of the ATDC Sensor

Important
• This adjustment is not necessary when a new Imaging Unit has been installed. (The
ATDC Sensor is automatically adjusted when the starter is charged and the Power
Switch turn ON.)
• The adjustment must be made whenever the currently used Imaging Unit has been
charged with new starter.
1139D020AA
1139D022CA
1139D019CA
NOTE
The I/U Counter available from the Consumables counter menu is automatically reset when
the ATDC Sensor gain adjustment has been completed.
The Full Size key can be used to alternately display the data on the Magnification Ratio
Indicator, either the ATDC Sensor output voltage or ATDC Sensor gain.
1. Load the starter.
2. On the control panel, press the Meter Count Key,
stop Key, 10-keys "0", 10-keys "0", stop Key, 10-
keys "0", 10-keys "1", 10-keys "1" and then "8" to
set the copier into the F8 Test Mode. (At this time,
the Multi-Copy Display shows "F8.")
3. Press the Start Key to let the copier make the
ATDC Sensor adjustment automatically. (It takes
about 5 min. for the copier to complete the adjust-
ment procedure.)
4. After the adjustment has been made, press the
Panel Reset Key twice (or turn OFF the Power
Switch) to return the copier back into the normal
mode.