FrameMaker Ver.5.5(PC) EP1054/EP1085/EP2030 SWITCHES ON PWBs/TECH. REP. SETTINGS
98.06.09
7

FUNCTION SETTING REQUIREMENTS AT REPLACEMENT OF PARTS

• If a part is replaced as part of troubleshooting and other service jobs, some parts require
that a Test operation be run and data values reentered and/or cleared.
Replacement Part
RAM
Board
Function
Memory clear
Initialize
Job program
User mode
Tech. Rep. Choice
Test F3
Test F5
Test F8
PM Counter
Clearing Parts/
Supplies Life
Counter "Pc"
Clearing Parts/
Supplies Life
Counter "St"
Clearing Parts/
Supplies Life
Counter "Cb"
Clearing Parts/
Supplies Life
Counter "Fu"
Adjust mode
: Required
1 : Including the replacement of the ATDC Sensor.
2 : Including the cleaning of Lamp Regulator and optical system.
Developer
PC
Cleaning
IU
Drum
Blade
1
S-34
Exposure
Fusing
Rollers
Lamp 2