10-6. Original Cover Angle Detection (23 cpm Copier Only)
The Original Cover Detecting Sensor detects the angle of the Original Cover as it is raised.
The following control is provided.
Original Cover raised to an angle of 15° or more:
The size of the original is read by the Original Size Detecting Sensors.
Original Cover raised to an angle of less than 15°:
When the Original Cover Detecting Sensor is activated, the original size data is latched and
Original Size Detecting Board UN2 transmits the size data to the Master Board. As soon as
the Size Reset Switch is turned ON, the size data is validated and the paper size is shown
on the control panel.
The paper size selected is reset when the Size Reset Switch is turned OFF.
Size Reset
Switch S108
Control Signal
PC111
PWB-A PJ18A-2
Control Signal
S108
PWB-A PJ23A-11B
Magnet
1139M093AA
Blocked
Unblocked
L
ON
L
M-32
Original Cover Detecting
Sensor PC111
WIRING DIAGRAM
H
12-B
OFF
WIRING DIAGRAM
H
6-C