C004E: Power Supply Unit Cooling Fan Motor 1'S Failure To Turn C004F: Power Supply Unit Cooling Fan Motor 2'S Failure To Turn - Minolta Di450 Service Manual

Hide thumbs Also See for Di450:
Table of Contents

Advertisement

(6)
C004E: Power Supply Unit Cooling Fan Motor 1's failure to turn
C004F: Power Supply Unit Cooling Fan Motor 2's failure to turn
Power Supply Unit Cooling Fan Motor 1
(M16)
Power Supply Unit Cooling Fan Motor 2
(M15)
M15
M16
C004E
Step
1
Power Supply Unit Cooling Fan Motor 1 rota-
tion: the voltage across PJ3C-1 on Power Sup-
ply Board and GND is DC24V after the
malfunction has been reset.
2
Power Supply Unit Cooling Fan Motor 1 rota-
tion: the voltage across PJ3C-3 on Power Sup-
ply Board and GND is DC5V after the
malfunction has been reset.
Relevant Electrical Parts
Master Board (PWB-A)
Power Supply Board (PWB-C)
CN115
1
3
2
2
3
1
Check
T-42
PWB-A
PJ6A-11(DC24V)
PJ6A-12(GND)
PJ6A-13(M15 LD)
PWB-C
PJ3C-1 (DC24V)
PJ3C-2 (GND)
PJ3C-3 (M16 LD)
4002C23TAA
Result
NO
Change Power Supply
Board.
YES Check motor for installa-
tion.
Change motor.
NO
Change Power Supply
Board.
Action

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Di550

Table of Contents