Fujitsu Siemens Computers PRIMERGY RX100 S4 User Manual page 141

Hide thumbs Also See for PRIMERGY RX100 S4:
Table of Contents

Advertisement

6
Set as follows:
1. In the [Write debugging information] section, select the memory dump file type.
• Complete memory dump (Recommended)
The whole system memory information is recorded to the memory dump file.
• Kernel memory dump
Only kernel memory is recorded to the memory dump file.
• Small memory dump (2MB or more)
Minimum information is recorded to the memory dump file.
Each time a fatal error occurs, a new file is created in the directory specified in [Small
dump directory].
2. In [Dump File] or [Small dump directory], specify the directory to save the memory
dump file, with its full path.
In case of kernel memory dump or complete memory dump, if [Overwrite any existing file]
is checked, debugging information is overwritten to the specified file every time.
7
Click [OK] to close the [Startup and Recovery] window.
8
Click [OK] to close the [System Properties] window.
9
Restart the system.
The setting is enabled after the system is restarted.
For OS Dump settings, even if reboot after obtaining the dump is set, it may not reboot at hard-
ware failure. Hardware failure should be fixed immediately, however, when uninterrupted oper-
ation is necessary, set reboot with Software Watchdog.
For details and setting procedures for Software Watchdog, refer to "3.4 Serious Error Handling
(ASR)" in "ServerView User's Guide" on the PRIMERGY Document & Tool CD.