Chapter 9 Operation and Maintenance
Non Fujitsu Siemens Memory Module
detected - Warranty restricted!
System battery is dead - Replace and run
SETUP
System CMOS checksum bad - Default
configuration used
System timer error
Real time clock error
Check date and time settings
Previous boot incomplete - Default
configuration used
CPU had been changed - Run SETUP
CPU mismatch detected
Baseboard Management Controller Error
234
table: List of POST Error Messages
Message
Contents
A memory error has occurred. This message appears when using
memory module other than Fujitsu products. Check to see that
the BIOS Setup Utility settings are correct ( "8.2 BIOS Setup
Utility" (pg.205)). If the message still appears, the baseboard
must be replaced. Contact an office listed in the "Contact
Information" of "Start Guide".
A battery error has occurred. Contact an office listed in the
"Contact Information" of "Start Guide".
A CMOS setting error has occurred. Correct the current set
value with the BIOS Setup Utility or restore the settings at the
time of purchase. If the message still appears, the baseboard
must be replaced. Contact an office listed in the "Contact
Information" of "Start Guide".
A system clock error has occurred. Turn the server off and turn
it back on. If the message still appears, the baseboard must be
replaced. Contact an office listed in the "Contact Information"
of "Start Guide".
A Real Time Clock (RTC) error has occurred. Enter the correct
date and time in the "8.2.2 Main Menu" ( pg.208) of the BIOS
Setup Utility. If the message still appears, the baseboard must be
replaced. Contact an office listed in the "Contact Information"
of "Start Guide".
A date and time error has occurred. Enter the correct date and
time in the "8.2.2 Main Menu" ( pg.208) of the BIOS Setup
Utility. If the message still appears, the baseboard must be
replaced. Contact an office listed in the "Contact Information"
of "Start Guide".
An error was detected due to incompleting POST at the previous
startup, or power off/reset was performed three times or more in
POST. After restoration, make sure to start BIOS setup and exit
after saving settings.
CPU has been changed. Check that the correct CPUs are
installed. If the message appears even after a correct installation,
change [Reset Configuration Data] on the "8.2.5 Advanced
Menu" ( pg.212) to [Yes] in the BIOS Setup Utility. If the
message still appears, the baseboard must be replaced. Contact
an office listed in the "Contact Information" of "Start Guide".
CPU frequency has been changed. Check that the correct CPUs
are installed. If so, update the BIOS. If the message appears
again, change [Reset Configuration Data] on the "8.2.5
Advanced Menu" ( pg.212) to [Yes] in the BIOS Setup Utility.
If the message still appears, the baseboard must be replaced.
Contact an office listed in the "Contact Information" of "Start
Guide".
A BMC error has occurred. Turn the server off and unplug the
power cables from the server. Turn the server back on. If the
message still appears, the baseboard must be replaced. Contact
an office listed in the "Contact Information" of "Start Guide".