Table 5.1 Mode Switch Settings - Fujitsu Primepower200 User Manual

Fujitsu primepower series servers user's manual
Table of Contents

Advertisement

CHAPTER 5 PRIMEPOWER400 Rackmount (4U) Server
(1) RESET switch (push button)
(2) MODE switch (3-position slider)
MANUAL
AUTO
SECURE
70
CAUTION
The RESET switch is used to reset the system to its initial state and is enabled or disabled by the
MODE switch described in "(2) MODE switch".
CAUTION
The MODE switch has three settings and is used to specify the run mode at power on or system
reboot, and to whether the POWER, RESET and REQUEST switches are "enabled" or "disabled".
MODE
POWER
switch
switch
Enabled
Enabled
Enabled
Disabled
Disabled
Disabled
Data Destruction
Pressing the RESET switch while the system is running may cause
data to be lost.
Data Destruction
Install the "Enhanced Support Facility" before operating the
system. Without ether package, incorrect front panel operations
and hardware errors may cause the system to shutdown or data to
be lost.
Table 5.1
MODE Switch Settings
RESET
REQUEST
switch
switch
The bootup sequence stops at an ok prompt
Enabled
after initial diagnostics are completed.
Use this mode to enter commands and make
settings from the ok prompt when performing
maintenance on the server unit.
Disabled
The OS is automatically booted after initial
diagnostics are completed.
Disabled
The OS is automatically booted after initial
diagnostics are completed. The TTY terminal
"break" and keyboard "STOP+A" commands
are disabled while Solaris is operating.
Operation mode

Advertisement

Table of Contents
loading

This manual is also suitable for:

Primepower400Primepower600

Table of Contents