CHAPTER 13
Troubleshooting

13.4 SCF Error Messages

The following table shows the messages that most commonly appear on the LCD panel when the SCF System
detects an error. Messages other than those shown may sometime be displayed.
SCF power supply unit configuration errors
234
The messages shown in Table 13.2 are displayed if there is a problem in the power supply unit
configuration.
Table 13.2
Power Supply Unit Configuration Error Messages
Message
Message
(1st line)
(2nd line)
SCF:alarm
FEP Config
0x-DDC Config
PPU3 Config
PPU5 Config
PPU12 Config
SCF:warning
0X-DDC Config
PPU3 Config
PPU5 Config
PPU12 Config
Cause
Insufficient FEP (Front End Power) units.
Insufficient DDC (DC-DC Converter) units
or DDC units inserted in incorrect slots.
Insufficient 3.3V PPU.
Insufficient 5.0V PPU.
Insufficient 12.0V PPU.
Excess DDC units.
Excess 3.3V PPU.
Excess 5.0V PPU.
Excess 12.0V PPU.