Power Control And Operator Panel Mode Switch - Fujitsu SPARC Enterprise M3000 Product Notes

Hide thumbs Also See for SPARC Enterprise M3000:
Table of Contents

Advertisement

Power Control and Operator Panel Mode Switch

Note – Before using the RCI function, see
When you use the remote power control utilizing the RCI function or the automatic
power control system (APCS), you can disable this remote power control or the
APCS by setting the mode switch to Service mode on the operator panel.
Disabling these features ensures that you do not unintentionally switch the system
power on or off during maintenance. Note that system power off with the APCS
cannot be disabled with the mode switch. Therefore, be sure to turn off automatic
power control via APCS before starting maintenance.
If you switch the mode while using the RCI or the automatic power control, the
system power is controlled as follows.
TABLE 6-1
Function
RCI
APCS
To use the RCI function, see the SPARC Enterprise
M3000/M4000/M5000/M8000/M9000 Servers RCI Build Procedure and the SPARC
Enterprise M3000/M4000/M5000/M8000/M9000 Servers RCI User's Guide.
To use the APCS, see the Enhanced Support Facility User's Guide for Machine
Administration Automatic Power Control Function (Supplement Edition).
Limitation for 1027A-Z/X1027A-Z
For PCIe Dual 10 Gigabit Ethernet Fiber XFP Low Profile Adapter (1027A-
Z/X1027A-Z), these maximum limits apply:
No more than six cards per a domain.
Do not use these cards in an External I/O Expansion Unit.
116
SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1121 • February 2016
RCI and APCS Control with Mode Switch
Mode Switch
Locked
Remote power-on/power-off
operations are enabled.
Automatic power-on/power-off
operations are enabled.
"Notes on RCI Function" on page
Service
Remote power-on/power-off
operations are disabled.
Automatic power-on is disabled, but
power-off remains enabled.
17.

Advertisement

Table of Contents
loading