Table 8.2 Installation Specifications Of The Primepower600 Rackmount (10U) Server - Fujitsu Primepower200 User Manual

Fujitsu primepower series servers user's manual
Table of Contents

Advertisement

CHAPTER 8 PRIMEPOWER600 Rackmount (10U) Server
8.3.2 Installation specifications
Table 8.2 and Table 8.3 show the installation specifications for the PRIMEPOWER600 Rackmount (10U) Server.
Table 8.2
*1:
*2:
*3:
148
 Take electrostatic prevention measures. Note that some carpets generate static electricity easily
and can cause the PRIMEPOWER600 Rackmount (10U) Server to malfunction.
 When moving the PRIMEPOWER600 Rackmount (10U) Server, do not pull on the front cover.
Otherwise, the Server may be damaged.
Installation Specifications of the PRIMEPOWER600 Rackmount (10U) Server (1/2)
Item
Weight
Power Supply
Frequency
Voltage
Max. Current
Leak Current
Frame Resistance
Temperature
Operating
Non-operating
Humidity
Operating
Non-operating
Vibration
Operating
Non-operating
Noise
Form Factor
Include Rack Rail weight.
If the ambient temperature exceeds 35 deg. C (95 deg. F) during operation, a warning message is
displayed. Take steps to rectify the problem immediately.
The indicated noise is the mean value of measurements obtained when the server unit is installed in
an 1800mm (71-inch) rack server in a low-noise anechoic chamber. The actual noise measured at
the installation site may be greater than the indicated value due to background noise and echoes.
Specification
108 kg (238.41 lb.) (max.)
(*1)
50/60 Hz (+2 ~ -4%)
Single phase
Single phase
±
AC100V (
10%)
AC200V (
19.0 A
9.5 A
²
3.5 mA
²
100Ω
û
5 ~ 35
C (+41 ~ +95 F) (*2)
û
0 ~ 50
C (+32 ~ +122 F)
20 ~ 80% RH (non-condensing)
8 ~ 80% RH (non-condensing)
0.2 G
0.4 G
55 db(A) (*3)
Rackmount (10U)
±