Table 13.6 Other Error Massages - Fujitsu Primepower200 User Manual

Fujitsu primepower series servers user's manual
Table of Contents

Advertisement

CHAPTER 13
Troubleshooting
Lithium battery
Other error messages
236
The messages shown in Table 13.5 are displayed when the voltage of the lithium battery has
dropped. Also, an alarm message notifying initialization of the calendar information will be
displayed when the power is turned on after replacing the lithium battery. If these messages are not
cleared after replacing the lithium battery, a poor battery cable connection is the probable cause.
Table 13.5
Message
Message
(1st line)
(2nd line)
SCF:alarm
LiBATT
SCF:warning
Calendar Initial
Message
Message
(1st line)
(2nd line)
SCF:idling...
xxx min. POWER
RCI Mainte Mode
I/O Power on
SCF:warning
Please Levelup
SCF:alarm
RCI Timeout
FMEM Protected
Syshalt xxxxxxxx
0x-CPU Config
I2C#x
SCF:stop
SCF Watchdog
BUSerr xxxxxxxx
ADRerr xxxxxxxx
Lithium Battery Error Messages
The voltage of the lithium battery has dropped.
The calendar information has been reset.
This message is displayed immediately after
the lithium battery is replaced.
Table 13.6
Other Error Massages
xxx minutes passed since the power was
restored.
The RCI mode has changed for maintenance.
Waiting for I/O units to power up.
Firmware upgrade processing failed.
Please try again.
Time-out detected by RCI communications.
Mounted flash memory is write-protected.
System HALT detected.
Mixed CPU types detected.
I2C diagnostics (x: I2C bus number).
SCF watchdog detected.
Bus error detected.
Address error detected.
Cause