5.3 Preparations for Use
This section describes the following:
Installation notes and specifications
Connecting the console
Turning power on and off
Installing the Enhanced Support Facility package
Enabling/disabling the break signal
LAN expansion note
5.3.1 Installation notes
CAUTION
Rack installation notes
Unit Damage
If the following notes are not observed the PRIMEPOWER400 Rackmount (4U)
Server may be damaged. Be sure to follow these notes.
The following instructions are intended to provide product safety requirements to be addressed
when the end-use product manufacturer installs this product in their equipment.
As the PRIMEPOWER400 Rackmount (4U) Server is installed in a closed or multi-unit rack
assembly, the ambient operating temperature inside of the rack environment may be greater
than the room temperature. So, consideration should be given to installing the
PRIMEPOWER400 Rackmount (4U) Server in an environment compatible with the
manufacturer's maximum rated ambient temperature.
– Consideration for adjustment of air conditions like air circulation should be given to
prevent the internal rack ambient temperature from exceeding the maximum operating
temperature of this unit.
– Maximum internal operating temperature of this unit: 35 deg. C (95 deg. F)
Installation of the PRIMEPOWER400 Rackmount (4U) Server should be such that the amount
of air flow required for safe operation of the PRIMEPOWER400 Rackmount (4U) Server is not
compromised.
– The PRIMEPOWER400 Rackmount (4U) Server has ventilation openings at the front and
rear faces of the unit.
– To prevent overheating, do not cover or close these ventilation openings.
Mounting of the PRIMEPOWER400 Rackmount (4U) Server in the rack should be such that a
hazardous condition does not result from uneven mechanical loading. To maintain the stability
of the entire rack, please fix the rack to the wall or floor by suitable means.
5.3 Preparations for Use
73