8.4.3 Adding memory modules

A total of 32 memory module slots are provided on the PRIMEPOWER600 Rackmount (10U) Systemboard.
IMPORTANT
The Expansion Systemboard must be first installed before the seventeenth and further memory
modules can be added.
When adding memory modules the following restrictions apply.
IMPORTANT
Operation for configuration other than those described below cannot be guaranteed.
 Each sequential group of 4 memory slots (#0-3, #4-7, #8-11, #12-15) must be either left empty or completely
filled with 4 identical memory modules.
8.4.4 Adding hard disk drives
Disk drive configuration
Hot-swapping hard disk drives
CAUTION
160
Up to six hot-swappable UltraSCSI disk drives can be added to the PRIMEPOWER600 Rackmount
(10U) Server. Each of the disk drive bays is provided with an ACTIVE LED and a FAULT LED.
The ACTIVE LED lights up (green) when a hard disk drive is operating (reading or writing). The
FAULT LED lights up according to the swapping procedure when hot-swapping a hard disk drive.
Hard disk drives installed on the PRIMEPOWER600 Rackmount (10U) Server are hot-swappable.
To enable hot-swapping, use the tools (machine administration) contained in the "Enhanced Support
Facility" to perform hot-swapping while monitoring the state of the ACTIVE and FAULT LEDs.
For details on how to swap hard disk drives, refer to the "Machine Administration Instructions"
included with the "Enhanced Support Facility".
Data Destruction
Data may be lost if hot-swapping of hard disk drives is not performed correctly.
Contact the service engineer if the hard disk drive must be hot-swapped.