Table of Contents

Advertisement

3. If a master valve or pump start relay is used, make this connection
in the same manner.
CAUTION: The pump start relay must be rated 24 Vac at
0.325A max. Never connect directly to the pump starter.
4. Route the wire cable into the controller through the large opening in
the base of the housing or through conduit if installed.
5. Leave about 8" of cable remaining in the cabinet. Remove the outer
jacket to expose about 6" of wire. Strip insulation back on each wire
to expose about
6. Secure the valve common wire to one of three terminals labeled
"VC/COM" and each valve wire to the applicable station number
terminal.
Master Valve/
Pump Relay
Terminal
Pump Start Relay
0.325 A (max.)
Master Valve
72
" of bare wire.
3
8
Control Valves
Valve Common Wire
Valve Common
Terminals