2.
Turn the Lower Line knob as needed to display the affected station
numbers.
01 02 03 04 05 06 07 08
SH SH –– –– –– –– –– ––
ALERT:
3.
A short circuit condition is indicated on stations 01 and 02. To view
additional stations, continue to turn the Lower Line knob.
4.
To resolve the problem, check the wiring connections and solenoid
condition of the affected valve and take the appropriate corrective
measures.
5.
To turn off the Alert message, press the COPY button.

Using the ET Function

The display screens provided within the ET function enable the current
ET values for daily and weekly watering operations to be reviewed and
the Kc factor of Custom Turf and Plants to be adjusted.
Viewing the Current Daily and Average Weekly ET Values
1.
Turn the Function Selector knob to the ET position to view the
following display (example):
CURRENT DAILY ET:
06-21-07 01:09:24
In this example, the Current Daily ET value being used by the
controller to calculate watering is 0.57. The lower lines shows the
date and time the last ET data download.
Note: ET data that is currently pending download will be indicated
with the letter "P."
3.
Turn the Upper Line knob right one stop to view the Average Weekly
ET value as shown the following display (example):
AVERAGE WEEKLY ET:
1.00
58
See Alert Menu
0.57