Toro TDC-100/200 User Manual

Toro TDC-100/200 User Manual

Toro sprinkler user manual

Advertisement

Quick Links

T T D D C C - - 1 1 0 0 0 0 / / 2 2 0 0 0 0
U U s s e e r r ' ' s s G G u u i i d d e e

Advertisement

Table of Contents
loading

Summary of Contents for Toro TDC-100/200

  • Page 1 T T D D C C - - 1 1 0 0 0 0 / / 2 2 0 0 0 0 U U s s e e r r ’ ’ s s G G u u i i d d e e...
  • Page 3: Table Of Contents

    Index Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4 General Editing - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4 Timing Mechanism Components - - - - - - - - - - - - - - - - - - - - - - - - - - 5 Mother Board Components - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6...
  • Page 4: Introduction

    With 10 irrigation programs, the TDC-100/200 allows programming flexibility. General Editing Pressing a menu key on the TDC-100/200 will display menu items. Items with fields containing values that can be edited are called Entry Fields. Use the Arrow Keys fields. Modify any selected value by scrolling through the selection using the Input Dial saved automatically when you exit an entry field or press another menu key.
  • Page 5: Timing Mechanism Components

    Timing Mechanism T DC-100/200 HOME %ADJUST Left and Right Arrows allow you to select the next entry field within the same menu line. Any changes will be saved after you exit that entry field. Up and Down Arrows allow you to scroll up and down through the menu items. LCD Panel is the display screen.
  • Page 6: Mother Board Components

    Daughter Board Daughter Board Components Power LED Daughter Board Fuse (8), 3.15A Fast-Blow Mother Board Mother Board Components Station Watering LED Pump ON LED Pump Pressure LED Rain Sensor LED Power LED PC Connection LED Tx LED Rx LED Mother Board Fuse, 3.15A Slow-Blow Timing Mechanism Cable Socket RS-232 Fiber/Wire Switch Pump Output...
  • Page 7: Power-Up Diagnostics

    TDC–100/200 System Booting The TDC-100/200 will initiate a diagnostic test automatically during power-up. This function will take approximately ten seconds and it can not be bypassed. If a problem is detected during the diagnostic test, it will be indicated on the display.
  • Page 8: System Settings

    System Settings System Settings allows you to set controller parameters such as Time, Date and Language. Use the Up or Down Arrows Use the Left and Right Arrow Use the Input Dial to select values when editing. Language: – Default, English. Future option, Spanish, French, German and Italian. Clock Set: –...
  • Page 9 Hold For: – Use this function to suspend controller operation and choose the suspension duration from Today, 02-30 days, Permanent or None. Reset Prg’s: – Use this function to reset all controller irrigation program by selecting Yes. After selecting Yes, press the Up or Down Arrows Reset All Programs to defaults...
  • Page 10: Station Settings

    Station Settings Station Settings allows you to set parameters specific to each station. Use the Up or Down Arrows Use the Left and Right Arrow Keys Use the Input Dial to select values when editing. S01 – Select the station you want to edit in this field. Choose from Station 01 through the controller maximum station count of 200.
  • Page 11: Scheduled Watering

    Scheduled Watering The TDC-100/200 features 10 fully-independent resident programs. With two types of programs to select from, you can further custom fit your irrigation programs to any landscape. • Standard Irrigation Program will activate a station or group of stations with six start times on a daily basis. Each station will water for the duration specified in hours, minutes and seconds.
  • Page 12 8. Press the Down Arrow to navigate between the Hour and Minute fields. Use Input Dial Delay duration. Station delay is the wait period when a station finished watering and when the next station is activated. In most situations, station delay is used to allow slow -shutting valves time to fully close before activating another station and also to allow the water source, such as a well, to recover.
  • Page 13: Grow-In Irrigation Program

    Grow In Irrigation Program Setting: Grow In Irrigation Program example: Create program 3 with stations 21–30 for 5 minutes each with no percent adjustment. Set the start time at 6:30 am and the end time at 4:00 pm. Set the delay for 2 hours and 15 minutes and the maximum simultaneous active station to 5.
  • Page 14: Manual Watering

    Manual Watering The Manual Watering functions are used for additional watering if the irrigation program is not sufficient. They can also be used to troubleshoot each station for proper operation. Pressing the Manual Watering Key will access three manual irrigation functions; Multi-Manual, Syringe and Program. M-Manual - Select M-Manual to activate a station or group of stations with a specified runtime.
  • Page 15: Manual Syringe

    Syringe - Choose Syringe to activate all the stations in a selected irrigation program for a specified runtime. Note: The Maximum number of simultaneous stations set in the program still applies. Manual Syringe Activation Directions Syringe activation example: Manually activate all the stations in Program 3 for 2 minutes each. Note: An irrigation program must be configured to activate Manual Syringe.
  • Page 16: (Percent) Adjust

    % (Percent) Adjust The percent adjust function allows you to fine tune irrigation programs. With weather conditions changing constantly, Percent Adjust allows you to tune your system easily without changing all the values in the program. Important: The settings do not override each other, instead, they multiple each other to get the effective adjustment. Example: Controller is set at 150%, Program is set at 125% and Station is set at 90%.
  • Page 17: Pause / Resume Key

    Pause / Resume Key The Pause command is used to suspend active program or manual irrigation. The Pause function allows the user to specify the pause duration. Pause / Resume Function Directions Pause function example: Program 01 has been manually activated. Pause program 01 for 30 minutes. 1.
  • Page 18: Stop Key

    Cancelling P01 STOP to escape 1 1 8 8 TDC-100/200 Action Allow the start of other programs, multi-manuals and syringe. If the start time of the paused program occur’s again while still on Pause, that runtime will be stacked (delayed until the first occurrence is completed).
  • Page 19: Diagnostics

    Diagnostics The diagnostics function allows the user to monitor Radio Link status, check the firmware version, troubleshoot stations using the Sequence Stations options, monitor the system’s water usage, monitor all system’s sensor status, monitor system’s voltages, check alarm status, clear alarms and execute a self diagnostics to the system. Menu: Station Alarms No Station Alarms Menu: RunDiagnostics...
  • Page 20: Fuse And Circuit Breaker Specifications

    Operation in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. © 2007 The Toro Company, Irrigation Division • An ISO-9000-Certified Facility Form Number 373-0379 Rev. C...

This manual is also suitable for:

Tdc-100Tdc-200

Table of Contents