Reinitialize Digital I/O; Emulate Mode Vs. Live Mode; Synchronizing: Pull Vs. Push - Extron electronics DMP 64 User Manual

Digital matrix processor
Hide thumbs Also See for DMP 64:
Table of Contents

Advertisement

Reinitialize Digital I/O

Should the script stop running for any reason, go to
select
To remove a digital I/O script from the DMP 64:
Only one digital I/O configuration can be active at a time. If the I/O activity needs to be
modified, remove the current configuration by:
1.
2.
3.

Emulate Mode vs. Live Mode

The DSP Configurator program has two operational modes,
live mode, the program has established a connection and is synced with the DMP 64.
Changes affect the device in real-time and changes in the current state of the device
are reflected in the DSP Configurator. In contrast, emulate mode allows the user to
work offline, creating or editing configurations that do not immediately affect DMP 64
operation.
The DSP Configurator program always starts in
functions of the DSP Configurator program are available without connecting to the
DMP 64. The user can build a configuration from the blank screen, or open an existing file
that contains the last configuration displayed plus saved presets. Settings and adjustments
are saved to a configuration file on the PC. When the saved file is opened in the
DSP Configurator program, the program restores all settings as the current configuration
(emulated if in
Live mode can be entered at any time after program launch, either with a blank
configuration, after creating a configuration, or after loading a previously saved
configuration file.
In emulate mode, the current state is titled
state is titled,

Synchronizing: Pull vs. Push

When switching to live mode after making changes to the current configuration in
emulate mode, either:
Live mode can also be used to tailor audio settings in real time while listening to the audio
output.
. This option is only available in live mode.
Reinitialize Digital I/O
From the Tools menu, click
Remove Digital I/O Configuration from the Device
If the DSP Configurator is connected to a device, the I/O configuration will be
removed. If it is not connected, a connection dialog box will appear.
Make certain the connection information is correct, then press
configuration script will be removed and a confirmation dialog box will appear.
mode or live if in
Emulate
Current State
.
data from the device and update the DSP Configurator program configuration.
Pull
This option downloads device settings from the DMP 64 and synchronizes it with the
DSP Configurator program overwriting the current DSP Configurator settings, or
data from the DSP Configurator program to the device, overwriting settings in
Push
the DMP 64.
Tools | Configure Digital I/O
, then select
Configure Digital I/O
mode. In emulate mode, all
Emulate
mode).
Live
Current Emulation
DMP 64 • Software Control
, then
and press
.
OK
OK
. The I/O
and
. In
Live
Emulate
. In live mode, the current
108