Stopping The Inverter On External Device Faults (External Fault Function) - Omron VARISPEED F7 User Manual

Vector control frequency inverter
Hide thumbs Also See for VARISPEED F7:
Table of Contents

Advertisement

Multi-Function Digital Inputs (H1-01 to H1-05)
Set Value
12
13
Application Precautions
Jog frequencies using FJOG and RJOG commands have the priority over other frequency references.
When both FJOG command and RJOG commands are ON for 500 ms or longer at the same time, the
Inverter stops according to the setting in b1-03 (stopping method selection).

Stopping the Inverter on External Device Faults (External Fault Function)

The external fault function activates the fault contact output and stops the Inverter operation. Using this func-
tion the inverter operation can be stopped on peripheral devices break down or other faults. The digital opera-
tor will display EFx (External fault [input terminal Sx]). The x in EFx shows the number of the terminal at
which the external fault signal is input. For example, if an external fault signal is input to terminal S3, EF3
will be displayed.
To use the external fault function, set one of the values 20 to 2F in one of the parameters H1-01 to H1-05 (Ter-
minal S3 to S7 function selection).
Select the value to be set in H1-01 to H1-05 from a combination of any of the following three conditions.
Signal input level from peripheral devices
External fault detection method
6
Operation after external fault detection
The following table shows the relationship between the combinations of conditions and the set value in H1-
.
Set
Value
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
* 1. Sets the input level at which faults are detected. (NO contact: External fault when ON; NC contact: External fault when OFF).
* 2. Set the detection method to detect faults using either constant detection or detection during operation.
Constant detection: Detects while power is supplied to the Inverter.
Detection during operation: Detects only during Inverter operation.
76
6-
FJOG command (ON: Forward run at jog frequency d1-17)
RJOG command (ON: Reverse run at jog frequency d1-17)
Input Level
Fault Detection Method (See
* 1
(See Note
)
Constant
NO Contact
NC Contact
Detection
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Function
Operation During Fault Detection
* 2
Note
)
Detection
Decelerate to
During
Stop (Fault)
Operation
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Control Methods
V/f
Open
V/f
with
Loop
PG
Vector
Yes
Yes
Yes
Yes
Yes
Yes
Continue
Coast to Stop
Fast Stop
Operation
(Fault)
(Fault)
(Warning)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Closed
Loop
Vector
Yes
Yes
Yes
Yes
Yes
Yes

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents