Adding/Subtracting A Fixed Speed To An Analog Reference (Trim Control) - Omron VARISPEED F7 User Manual

Vector control frequency inverter
Hide thumbs Also See for VARISPEED F7:
Table of Contents

Advertisement

Output frequency
Upper limit (d2-01)
Accelerates to
lower limit
Lower limit (d2-02)
Forward operation/stop
UP command
DOWN command
Speed agree*
Power supply
* The speed agree signal turns ON when the motor is not accelerating/decelerating while
the run command is ON.

Adding/Subtracting a Fixed Speed to an Analog Reference (Trim Control)

The trim control function adds or subtracts the value of parameter d4-02 to/from an analog frequency refer-
ence.
To use this function, set two of the parameters H1-01 to H1-05 (multi-function digital terminal inputs S3 to S7
function selection) to 1C (Trim Control Increase command) and 1D (Trim Control Decrease command). Be
sure to allocate two terminals so that the Trim Control Increase command and Trim Control Decrease com-
mand are used as a pair. Otherwise an OPE03 alarm will be displayed.
Related Parameters
Parameter
No.
d4-02
Trim control speed limits
Multi-function Digital Inputs (H1-01 to H1-05)
Set Value
1C
Trim control increase
1D
Trim control decrease
Fig 6.70 UP/DOWN Commands Timing Chart
Name
Function
Same
frequency
Reference
frequency reset
Change
Factory
during
Setting
Opera-
V/f
tion
10%
No
A
V/f
Yes
Yes
Control Methods
Open
Closed
V/f with
Loop
Loop
PG
Vector
Vector
A
A
A
Control Methods
V/f
Open
Closed
with
Loop
Loop
PG
Vector
Vector
Yes
Yes
Yes
Yes
Yes
Yes
6-
6
73

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading