User Parameters

Factory settings are given in the following table. These are factory settings for a 200 V Class Inverter with 0.4
kW (open loop vector control).
No.
A1-00
Language selection for Digital Operator display
A1-01
Parameter access level
A1-02
Control method selection
A1-03
Initialize
A1-04
Password
A1-05
Password setting
A2-01 to
User specified parameters
A2-32
b1-01
Reference source selection
b1-02
RUN command source selection
b1-03
Stopping method selection
b1-04
Prohibition of reverse operation
b1-05
Operation selection for setting frequencies equal or lower than E1-09
b1-06
Control input scan
b1-07
Operation selection after switching to remote mode
b1-08
Run command selection in programming modes
b2-01
Zero speed level (DC injection braking starting frequency)
b2-02
DC injection braking current
b2-03
DC injection braking time at start
b2-04
DC injection braking time at stop
b3-01
Speed search selection (current detection or speed calculation)
b3-02
Speed search operating current (current detection)
b3-03
Speed search deceleration time (current detection)
b3-05
Speed search wait time (current detection or speed calculation)
b3-10
Speed Search Compensation Gain (speed calculation only)
b3-14
Speed Search Rotating Selection Direction
b3-17
Speed search retrial current level
b3-18
Speed search retrial detection time
b3-19
Number of speed search retrials
b4-01
Timer function ON-delay time
b4-02
Timer function OFF-delay time
b5-01
PID control mode selection
b5-02
Proportional gain (P)
b5-03
Integral (I) time
b5-04
Integral (I) limit
b5-05
Differential (D) time
b5-06
PID limit
b5-07
PID offset adjustment
b5-08
PID delay time constant
b5-09
PID output characteristics selection
b5-10
PID output gain
b5-11
PID reverse output selection
Name
Factory
Setting
Setting
0
2
2
0
0
0
1
1
0
0
0
1
0
0
0.5 Hz
50%
0.00 s
0.50 s
*1
*1
2.0 s
0.2 s
1.10
1
150%
0.01s
0
0.0 s
0.0 s
0
1.00
1.0 s
100.0%
0.00 s
100.0%
0.0%
0.00 s
0
1.0
0
10
7
10-