Shielded twisted-pair wires must be used for signal lines.
Do not use the pulse generator's power supply for anything other than the pulse generator (encoder). Using
it for another purpose can cause malfunctions due to noise.
The length of the pulse generator's wiring must not be more than 100 meters.
The direction of rotation of the PG can be set in user parameter F1-05 (PG Rotation). The factory preset if
for motor forward rotation, A-phase advancement.

Wiring Terminal Blocks

Do not use more cables longer than 100 meters for wiring the PG (encoder) and keep them separate from
power lines.
Use shielded, twisted-pair wires for pulse inputs and pulse output monitor wires, and connect the shield to the
shield connection terminal.
Wire Sizes (Same for All Models)
Terminal wire sizes are shown in
Pulse generator power supply
Pulse input terminal
Pulse monitor output terminal
Shield connection terminal
Straight Solderless Terminals
We recommend using straight solderless terminal on signal lines to simplify wiring and improve reliability.
Refer to
Table 2.8
36
2-
PG-X2
TA1
IP12
IG
IP5
A (+)
A (-)
B (+)
B (-)
Z (+)
Z (-)
IG
TA3
Fig 2.21 PG-X2 Wiring Using a 5 V External Power Supply
Table
Terminal
Terminal
Screws
-
M3.5
for specifications.
PG power
supply
AC
0V +12V
1
0 V
2
Capacitor for
+12 V
3
momentary
+
power loss
+
4
-
5
+
6
-
7
+
8
-
9
10
2.15.
Table 2.15 Wire Sizes
2
Wire Thickness (mm
)
Stranded wire: 0.5 to 1.25
Single wire: 0.5 to 1.25
0.5 to 2
PG
Wire Type
• Shielded, twisted-pair wire
• Shielded, polyethylene-covered, vinyl
sheath cable
(KPEV-S by Hitachi Electric Wire or
equivalent)