Using an Fast Stop

Set a digital input terminal (H1-
tion time set in C1-09. If inputting the fast stop with an NO contact, set the multi-function digital input termi-
nal (H1-
) to 15, and if inputting the fast stop with an NC contact, set the multi-function digital input
terminal (H1-
) to 17.
After the fast stop command has been input, operation cannot be restarted until the Inverter has stopped. To
cancel the fast stop, turn OFF the run command and emergency stop command.
Related parameters
Parameter
No.
C1-09
Multi-function Digital Inputs (H1-01 to H1-05)
Set
Value
15
Fast Stop, NO contact
17
Fast Stop, NC contact
) to 15 or 17 (Fast stop) to decelerate to stop using the fast stop decelera-
Name
Fast stop time
Function
Control Methods
Change
Factory
during
V/f with
Setting
Opera-
V/f
PG
tion
10.0 s