Torque Detection: L6
Param-
eter
Num-
Display
ber
Torque
detection
selection 1
L6-01
Torq Det 1 Sel
5
Torque detec-
tion level 1
L6-02
Torq Det 1 Lvl
Torque detec-
tion time 1
L6-03
Torq Det 1
Time
Torque detec-
tion selection
L6-04
2
Torq Det 2 Sel
Torque detec-
tion level 2
L6-05
Torq Det 2 Lvl
Torque detec-
tion time 2
L6-06
Torq Det 2
Time
58
5-
Name
Description
0: Overtorque/undertorque
detection disabled.
1: Overtorque detection only
with speed agreement;
operation continues
(warning is output).
2: Overtorque detected
continuously during
operation; operation
continues
(warning is output).
3: Overtorque detection only
with speed agreement;
output stopped upon
detection.
4: Overtorque detected
continuously during
operation; output stopped
upon detection.
5: Undertorque detection
only with speed agree-
ment; operation continues
(warning is output).
6: Undertorque detected
continuously during
operation; operation
continues
(warning is output).
7: Undertorque detection
only with speed agree-
ment; output stopped upon
detection.
8: Undertorque detected
continuously during
operation; output stopped
upon detection.
Vector control: Motor rated
torque is set as 100%.
V/f control: Inverter rated cur-
rent is set as 100%.
Sets the overtorque/under-
torque detection time.
See L6-01 to L6-03 for a
description.
Change
Setting
Factory
during
Range
Setting
Opera-
V/f
tion
0 to 8
0
No
A
0 to
150%
No
A
300
0.0 to
0.1 s
No
A
10.0
0 to 8
0
No
A
0 to
150%
No
A
300
0.0 to
0.1 s
No
A
10.0
Control Methods
MEMO-
V/f
Open
Closed
BUS
with
Loop
Loop
Register
PG
Vector
Vector
A
A
A
4A1H
A
A
A
4A2H
A
A
A
4A3H
A
A
A
4A4H
A
A
A
4A5H
A
A
A
4A6H
Page
6-49
6-49
6-49
6-49
6-49
6-49