Removal of PCBs

Procedure
Step
1. Remove the main PCB.
1
Open the cover of the
electrical box.
2
Remove the 3 screws.
3
Unfasten the 4 hooks.
4
Lift up the main PCB.
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Hook
Outdoor Unit: 3MXS24JVJU, 4MXS32GVJU
Hook
 Unfasten the 4 hooks. The
hooks are marked with .
(R14617)
Main PCB
(R10404)
(R10405)
(R10406)
Points
(R6427)