Service Diagnosis - Daikin SUPER MULTI NX CTXS07JVJU Service Manual

Super multi nx g-series / j-series
Hide thumbs Also See for SUPER MULTI NX CTXS07JVJU:
Table of Contents

Advertisement

1. Troubleshooting with LED .......................................................................135
2. Problem Symptoms and Measures .........................................................137
3. Service Check Function ..........................................................................138
4. Code Indication on Remote Controller ....................................................144
5. Troubleshooting for Indoor Unit...............................................................146
6. Troubleshooting for Outdoor Unit............................................................156
7. Check ......................................................................................................191
133

Service Diagnosis

1.1 Indoor Unit................................................................................................ 135
1.2 Outdoor Unit ............................................................................................. 136
3.1 ARC452 Series Remote Controller .......................................................... 138
3.2 ARC433 Series Remote Controller .......................................................... 141
4.1 Indoor Unit................................................................................................ 144
4.2 Outdoor Unit ............................................................................................. 145
5.1 Indoor Unit PCB Abnormality ................................................................... 146
5.3 Fan Motor or Related Abnormality ........................................................... 150
5.4 Thermistor or Related Abnormality (Indoor Unit)...................................... 153
6.1 Refrigerant Shortage ................................................................................ 156
6.2 Low-voltage Detection or Over-voltage Detection.................................... 159
Anti-icing Function in Other Rooms.......................................................... 162
6.5 Anti-icing Function.................................................................................... 163
6.6 Outdoor Unit PCB Abnormality (24/32 Class Only).................................. 165
6.7 OL Activation (Compressor Overload) ..................................................... 166
6.8 Compressor Lock ..................................................................................... 167
6.9 DC Fan Lock ............................................................................................ 168
6.10 Input Overcurrent Detection ..................................................................... 169
6.11 Four Way Valve Abnormality (18 Class Only) .......................................... 170
6.12 Discharge Pipe Temperature Control....................................................... 172
6.13 High Pressure Control in Cooling ............................................................. 173
6.15 Position Sensor Abnormality .................................................................... 176
6.16 CT or Related Abnormality ....................................................................... 179
6.17 Thermistor or Related Abnormality (Outdoor Unit)................................... 181
6.18 Electrical Box Temperature Rise.............................................................. 183
6.19 Radiation Fin Temperature Rise .............................................................. 186
6.20 Output Overcurrent Detection .................................................................. 189
7.1 Thermistor Resistance Check .................................................................. 191
SiUS12-928_B
Part 6
Service Diagnosis

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents