Removal Of Coils / Thermistors - Daikin SUPER MULTI NX CTXS07JVJU Service Manual

Super multi nx g-series / j-series
Hide thumbs Also See for SUPER MULTI NX CTXS07JVJU:
Table of Contents

Advertisement

Outdoor Unit: 2MXS18GVJU
1.6

Removal of Coils / Thermistors

Procedure
Step
1
Remove the screw and
remove the four-way
valve coil.
2
Remove the screw and
remove the defrost
solenoid valve coil.
Pull out the electronic
3
expansion valve coil for
each room.
4
Remove the discharge
pipe thermistor.
215
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Electronic
expansion
valve coil
Fixture
Discharge pipe
thermistor
Four way
valve coil
(R2194)
Defrost
solenoid
valve coil
(R2195)
 Place the thermistor so that its
edge comes up to the edge of
the fixture.
(R2196)
 Be careful not to lose the
fixture for the thermistor.
Thermistor
Pipe
(R10367)
SiUS12-928_B
Points
Fixture
(R10536)
Removal Procedure