Field Settings
5.2.3 When 2 Units are Installed in 1 Room
Outline
When 2 indoor units are installed in 1 room, 1 of the 2 indoor units and the corresponding wireless
remote controller can be set for different address.
Both the indoor unit PCB and the wireless remote controller need alteration.
The method of address setting varies depending on the type of indoor unit and the series of wired
remote controller. Refer to the following pages for the appropriate indoor unit and wireless remote
controller.
CTXS/FTXS
(1) Remove the front grille.
Series
(2) Remove the electrical box.
(3) Remove the shield plate of the electrical box.
(4) Cut the address setting jumper JA on the PCB.
CTXS-J, CTXS/FTXS-H Series
FTXS15/18LVJU
 Cut the jumper JA on PCB.
CDXS/FDXS
Series
265
JA
Address
EXIST
1
CUT
2
JB
JA
JC
JA
FDXS-D series
ADDRESS
JA
FDXS / CDXS-L series
ADDRESS : JA
JA
EXIST
CUT
CTXS07LVJU, FTXS09/12LVJU
(R17414)
(R9665)
1
2
SiUS12-928_B
JB
JA
JC
1
2
3
(R17415)
Trial Operation and Field Settings
(R17375)