Removal of Electrical Box / PCBs / Swing Motors

4. Removal of Electrical Box / PCBs / Swing Motors
Procedure
Step
1. Remove the electrical
box.
1
Remove the screw and
remove the service
cover.
Remove the screw and
2
remove the drip proof
plate.
3
Pull out the indoor heat
exchanger thermistor.
Remove the screw of
4
the earth wire.
Remove the 4 screws
5
of the connection wires.
Remove the screw of
6
the wire retainer.
8
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Indoor heat exchanger thermistor
Earth wire
Service cover
(R13574)
(R13575)
Drip proof
plate
(R11343)
Connection
wire
Wire
retainer
(R17633)
Si041143
Points
Be careful not to lose the clip
of the thermistor.
Clip
(R11268)
Removal Procedure