Service Check Function
Check Method 2
1. Press the 3 buttons (TEMP
2. Press the [TEMP]
3. Diagnose by the sound.
4. Press the [MODE] button.
139
The left-side number blinks.
 or  button and change the number until you hear the two consecutive
beeps or the long beep.
beep : The left-side number does not correspond with the error code.
two consecutive beeps : The left-side number corresponds with the error code but the
long beep : Both the left-side and right-side number correspond with the error code.
The numbers indicated when you hear the long beep are the error code.
Error codes and description  Refer to page 144, 145.
The right-side number blinks.
 , TEMP  , MODE) at the same time to enter the diagnosis mode.
right-side number does not.
SiUS12-928_B
(R14550)
(R9430)
(R14551)
(R14552)
(R9429)