Daikin SUPER MULTI NX CTXS07JVJU Service Manual page 139

Super multi nx g-series / j-series
Hide thumbs Also See for SUPER MULTI NX CTXS07JVJU:
Table of Contents

Advertisement

CDXS-L, FDXS-L Series
 COOL/HEAT mode lock
The COOL/HEAT mode lock requires initial programming during installation. Please consult your authorized dealer for
assistance. The COOL/HEAT mode lock sets the unit forcibly to either COOL or HEAT operation. This function is convenient when
you wish to set all indoor units connected to the multi system to the same operation mode.
NOTE
• The COOL/HEAT mode lock cannot be activated together with the priority room setting.
 Priority room setting
The priority room setting requires initial programming during installation. Please consult your authorized dealer for assistance.
The room designated as the priority room takes priority in the following situations.
Operation mode priority
• As the operation mode of the priority room takes precedence, the user can select a different operation mode from other
rooms.
[Example]
• Room A is the priority room in the examples.
When COOL operation is selected in room A while operating the following modes in room B, C and D :
Operation mode in room B, C and D
COOL or DRY or FAN
HEAT
AUTO
Priority when POWERFUL operation is used
[Example]
• Room A is the priority room in the examples.
The indoor units in rooms A, B, C and D are all operating. If the unit in room A enters POWERFUL operation, operation
capacity will be concentrated in room A. In such a case, the cooling (heating) efficiency of the units in room B, C and D may
be slightly reduced.
Priority when using OUTDOOR UNIT QUIET operation
[Example]
• Room A is the priority room in the examples.
Just by setting the unit in room A to QUIET operation, the air conditioner starts OUTDOOR UNIT QUIET operation.
You don't have to set all the operated indoor units to QUIET operation.
131
Status of room B, C and D when the unit in room A is in COOL operation
Current operation mode maintained
The unit enters standby mode. Operation resumes when the room A unit stops operating.
If the unit is set to COOL operation, it continues. If the unit is set to HEAT operation, it enters standby
mode. Operation resumes when the room A unit stops operating.
SiUS12-928_B