Download Print this page

Removal Of Electrical Box / Pcbs / Swing Motors - Daikin FT15HV2S Service Manual

4.2/5.0/6.0/7.1/8.0/9.0 kw class 15000 btu/h class removal procedure

Advertisement

Si04-855

4. Removal of Electrical Box / PCBs / Swing Motors

Procedure
Step
1. Remove the electrical
box.
Remove the screw and
1
remove the drip proof
plate.
Cut the clamp.
2
3
Pull out the indoor heat
exchanger thermistor.
Remove the screw of
4
the earth wire.
Remove the screws of
5
the connection wires.
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Indoor heat exchanger thermistor
Earth wire
Removal of Electrical Box / PCBs / Swing Motors
Preparation
Remove the front grille
according to the "Removal of
Front Grille".
(R2770)
Drip proof plate
(R2771)
The locations of the clamp
and the indoor heat
exchanger thermistor are
different depending on the
model.
(R6707)
Be careful not to lose the clip
for the thermistor.
Connection
Clip
wire
Wire fixture
(R17175)
Points
(R11234)
9

Advertisement