Programmable Unit - A&D GF-30K Instruction Manual

Gx-k / gf-k series high resolution industrial balance
Table of Contents

Advertisement

14. Programmable Unit

This is a programmable unit conversion function. It multiplies the weighing data in kilograms by an
arbitrary coefficient set in "Programmable unit (
The coefficient must be within the range between the minimum and maximum shown below. If the
coefficient set is beyond the range, an error is displayed and the balance returns to the coefficient
setting mode, prompting to enter an appropriate value. A coefficient of 1 was set at the factory.
GX-8K
GF-8K
GX-8K2
GX-12K
GF-8K2
GF-12K
Operation
Step 1 Press and hold the
then release the key.
Step 2 Press the
Step 3 Press the
Confirming the coefficient
Step 4 The current coefficient is displayed with the first digit blinking.
When it is not to be changed, press the
When it is to be changed, press the
Setting the coefficient
Step 5 Set the coefficient using the following keys.
SAMPLE
RE-ZERO
key ....... To change the decimal point position.
MODE
key ........ To store the new coefficient, display
PRINT
key ........... To cancel the new coefficient and go to step 6.
CAL
Quitting the operation
Step 6 The balance displays
function and return to the weighing mode.
Using the function
Press the
MODE
Perform weighing as described in "6-1. Basic Operation (Gram Mode)". After weighing, the
balance displays the result (weighing data in kilograms
Model
GX-10K
GF-10K
GX-20K
GX-30K
GF-20K
GF-30K
GX-32K
GF-32K
SAMPLE
key several times to display
SAMPLE
key to enter the mode to confirm or set the coefficient.
PRINT
key .... To select a digit to change the value.
The selected digit blinks.
key ... To change the value.
Each time the switch is pressed, the
decimal point position changes as follows:
and go to step 6.
. Press the
Unit
key to select the programmable-unit (no display on the unit section).
)" of the function table and displays the result.
mlt
Minimum coefficient Maximum coefficient
0.000001
key until
of the function table is displayed,
ba5fnc
key and go to step 6.
CAL
key and go to step 5.
RE-ZERO
key to exit the programmable-unit
CAL
x
74
100000
10000
.
mlt
end
coefficient).
1000
Store

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents