.      3  
6-2-4

Copying the Memory Table

Reference
Reference
Word
n+1
n+2

Program operation
When the program is executed by displaying the screen on the PT, the following
operation is performed.
(1) Each time contact 00100 comes ON, the display on the NT600S changes to
the next item in the following sequence.
NT20S
NT600S
(2) Each time contact 00101 comes ON, the display on the PT changes to the
next item in the following sequence.
NT610C
NT610G
The following describes the procedure to change displayed numerals or character
-strings by copying the contents of the memory table.
Numerals and character-strings can be changed also by changing the contents of
the allocated words. Refer to "Changing displayed numerals or character -strings"
explained before.
To change the numerals or character-strings displayed on the NT600S, copy the
data between the numeral or character-string memory tables by using the "copy
memory table setting" of the PT status control area.
NT600S
Memory table
copy source
A
A
Copy destination
A
(for display)
Write a memory table number etc. to the copy memory table setting area in the PT
status control area in the PC memory. Data will be copied between the memory
tables in the NT600S and the displayed value will change accordingly.
This procedure is convenient to switch predetermined values or character-strings
according to the situation. By preparing several units of contents, various con-
tents can be displayed by switching them to suit the situation.
["Copy memory table setting" of the PT status control area]
15 14 13 12 11 10 9
8
7
6
0
Copy source memory table # (3-digit BCD)
Copy type
Copy destination memory table # (3-digit BCD)
Copy type:
0: Copy between the character-string memory tables
1: Copy between the numeral memory tables
Copy source and destination memory table numbers: 000 to 127
Character-string memory table: 000 to 255
Numeral memory table: 000 to 511
NT610G
NT610C
NT600S
PC
PT status control area
Screen switch setting
Copy memory
table setting
PT status control setting
5
4
3
2
1
0 Bit
Copy memory
table setting
Section 5-2
NT20S
Copy source number
Copy destination number

Advertisement

Table of Contents
loading

Table of Contents