Initialization by Using the DIP Switch (Forced Initialization)

Note
Operation 1. Set DIP SW2-1 on the NT600S to ON and turn the power ON.
If "No" is selected, the memory initialization will be canceled and the NT600S re-
turns to the "Memory initialization".
[ MEMORY INITIALIZATION MENU ]
Quit
Screen Data Memory
Memory T ables
Display History
Memory Switches
After initialization of the screen data memory, the system enters the operation
mode. At this point, nothing is displayed on the screen of the NT600S.
When the screen data memory initialization has been completed, transfer the
screen data from the support tool.
If the screen data cannot be initialized for any reason, the message "An Error Oc-
cur Initializing Memory" is displayed.
Be sure to turn the power OFF before setting the NT600S DIP switch.
Set the DIP switch as follows to initialize the screen data memory.
Initialize the Screen Data Memory?
Confirm
Cancel
The screen data memory was
initialized.
Turn off the DIP-Switch 2-1
and push the reset switch,
then NT600S starts up normally.
2. Turn the NT600S power to OFF.
3. Set NT600S DIP SW2-1 to OFF and turn the power ON.
Section 3-4
Upon completion of image data
memory initialization, the
NT600S returns to the "Memory
Initialization Menu".
Select "Confirm". The screen
data memory is initialized. Dur-
ing the initialization, the "Initial-
izing ..." message will be dis-
played.