Lubrication; Checking The Emergency Stop Switch - JUKI AP-876/IP-420 Instruction Manual

Table of Contents

Advertisement

3-10. Lubrication

4
Remove filler cap 1 . Add JUKI New Defrix Oil No. 1 through fill opening 2 untl the ol level reaches the center of
ol gauge 3 . In addition, when you bring a new machine into use, be sure to supply oil through fill opening 4 by
approxmately 0 cc beforehand.
Be sure to use JUKI genuine oil. If you use any oil other than the specified oil, a trouble can
result.

3-11. checking the emergency stop switch

1
Emergency stop switch
oFF state
Emergency stop switch
oN state
1
When the red button of emergency stop swtch 1 s
strongly pressed as far as t goes, the swtch s placed
n ts ON state. When the button s turned clockwse,
the swtch s placed n ts OFF state.
Check to be sure that emergency stop swtch 1 s n ts
OFF state.
If emergency stop swtch 1 s n ts ON state, the op-
eraton panel screen wll not lght up even f the power
swtch s turned ON.
0