5-7. CUE Head Head-to-tape Contact Adjustment

Notes
. The CUE head head-to-tape contact adjustment is closely related to the height, azimuth and position
adjustments of the CUE head.
. After carry out the CUE head head-to-tape contact adjustment, be sure to carry out the adjustments or
checks of the CUE head.
Tools
. Alignment tape, ZR2-1 (NTSC)
. Alignment tape, ZR2-1P (PAL)
. Torque screwdriver bit (for M2)
. Torque screwdriver (for 3 kg)
. TP tool
. Oscilloscope
Setting
1. Turn the power off.
2. Connect the 8-pin connector of the TP tool to the connector CN7 on the HN-260 board.
3. Connect the 5-pin connector of the TP tool to the connector CN3 on the CTL-10 board.
4. Select the switches S1-1 and S1-2 on the HN-260 board to the OFF.
5. Connect an oscilloscope.
CH-1: PB CUE/TP tool
TRIG: CH-1
6. Turn the power on.
7. Insert the alignment tape ZR2-1/P.
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
: 8-960-073-11
: 8-960-073-61
: J-6325-380-A
: J-6325-400-A
: J-6420-910-A
5-7. CUE Head Head-to-tape Contact Adjustment
5-25