5. FE Head Installation
Insert two bosses of the FE head into the longitudi-
nal hole of the entrance head assembly, and tighten
the one screw.
The standard tightening torque value :
9 x 10
6. Entrance Head Assembly Installation
(1) Attach the entrance head assembly with the
mechanism deck using the two screws.
The standard tightening torque value :
9 x 10
(2) Attach the connector.
Adjustment After Replacement
7. Tape Running Adjustment
(Refer to section 5-1.)
DVW-790WS/709WS/707 P2V1
DVW-790WSP/709WSP/707P P2V1
DVW-707:
DVW-709WS: 10001 through 10125
DVW-790WS: 10001 through 10160
_2
N.m {0.9 kgf.cm}
_2
N.m {0.9 kgf.cm}
DVW-707:
DVW-709WS: 10126 and higher
DVW-790WS: 10161 and higher
10001 through 10055
DVW-707P:
DVW-709WSP: 40001 through 40255
DVW-790WSP: 40001 through 40510
Boss
Boss
Longitudinal hole
M 2x5
10056 and higher
DVW-707P:
DVW-709WSP: 40256 and higher
DVW-790WSP: 40511 and higher
Boss
Boss
Longitudinal hole
M 2x5
4-2. Parts Replacement
40001 through 40190
40191 and higher
4-111