Single-Step Feed - Mitsubishi Electric MR-J2S-CP Instruction Manual

Melservo j2-super series
Table of Contents

Advertisement

6. MR Configurator (SERVO CONFIGURATION SOFTWARE)

6.7.5 Single-step feed

Operation is performed in accordance with the preset point table No.
Click "Test" on the menu bar and click "Single-step Feed" on the menu.
When the above choices are made, the following window appears.
a)
(1) Point table No. setting ( a) )
Enter the point table No. into the "Point table No." input field and press the enter key.
(2) Servo motor start ( b) )
Click the "Start" button to rotate the servo motor.
(3) Temporary stop of servo motor ( c) )
Press the "Pause" button to stop the servo motor temporarily.
Click the "Start" button to resume rotation.
(4) Servo motor stop ( d) )
Click the "Pause" button again during a temporary stop of the servo motor to clear the remaining
moving distance.
(5) Single-step feed window closing ( e) )
Click the "Close" button to cancel the single-step feed mode and close the window.
POINT
In the jog operation mode, do not rewrite data from the point table list
screen or the servo amplifier's front panel. Otherwise, the set values are
made invalid.
The servo motor will not operate if the forced stop (EMG), forward
rotation stroke end (LSP) and reverse rotation stroke end (LSN) are off.
Make automatic ON setting to turn on these devices or make device
setting to assign them as external input signals and turn ON across these
signals and SG. (Refer to section 6.6.)
b)
c)
d)
6 - 18

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents