External Digital Display (Mr-Dp60) - Mitsubishi Electric MR-J2S-CP Instruction Manual

Melservo j2-super series
Table of Contents

Advertisement

14. OPTIONS AND AUXILIARY EQUIPMENT

14.1.7 External digital display (MR-DP60)

The data equivalent to the servo amplifier status display can be displayed on the MR-DP60. When using
the MR-DP60, set " 1
selected in parameter No.18.
(1) Specifications
Display
Power supply
Communication
Operating temperature / humidity range
Storage temperature range
(2) Connection example
NFB
(Note)
Power supply
Note. Refer to section 1.2 for the power supply specification.
(3) Terminal arrangement
TB1
TXD TXD RXD RXD P5 LG
Note. The 5VDC output is designed for the internal control circuit and used to make a voltage check, etc. Do not use this terminal to
supply a voltage to the other equipment.
4" in parameter No. 16. The items that appear at the time of power-on can be
Item
Permissible voltage fluctuation
Current consumption
Interface
Baud rate
Bit length
Protocol
Communication commands
MC
L
L
L
L
L
TB2
Red seven-segment LED, signed, six digits
Single-phase, 85 to 253VAC, 50/60Hz
Within 200mA
Conforms to RS-422
4800bps, asynchronous
Start bit 1, date bit 8, parity bit 1, stop bit 1
MELSERVO protocol
Commands dedicated to MELSERVO
0
to
60
(32 to 140 ),
90%RH or less, non-condensing
5
to
70
1
Servo amplifier
2
3
11
21
CN3
5
RDP
RDN
15
9
SDP
19
SDN
LG
1
Plate
SD
Signal
L
1
RXD
L
2
RXD
TXD
TXD
P5
LG
14 - 30
Specifications
(23 to 158 )
Description
L
1
100 to 230VAC power input
L
2
Ground
Receive signal input
Inverse receive signal input
Inverse transmission signal output
Transmission signal output
5VDC output (Note)
Control common
External digital display
MR-DP60
L
1
L
2
TXD
TXD
RXD
RXD
LG

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents