5.2.3 S-pattern acceleration/deceleration

In servo operation, linear acceleration/deceleration is usually made. By setting the S-pattern
acceleration/deceleration time constant (parameter No.14), a smooth start/stop can be made. When the S-
pattern time constant is set, smooth positioning is executed as shown below. When the S-pattern
acceleration/deceleration time constant is set, the time from when the positioning starts until the
movement finish (MEND) is output will increase by the time equivalent to the S-pattern time constant
setting.

5.2.4 Analog output

The servo status can be output to two channels in terms of voltage. The servo status can be monitored
using an ammeter.
(1) Setting
Change the following digits of parameter No.17.
Parameters No.31 and 32 can be used to set the offset voltages to the analog output voltages. The
setting range is between
Parameter
Parameter No.31
Parameter No.32
Acceleration time
constant
Rated
speed
Preset
speed
Servo motor
speed
0 [r/min]
Ta
Ta Ts
Ta: Time until preset speed is reached
Tb: Time until stop
Ts: S-pattern acceleration/deceleration time constant
Parameter No. 17
0
0
999 and 999mV.
Used to set the offset voltage for the analog monitor 1 (MO1) output.
Used to set the offset voltage for the analog monitor 2 (MO2) output.
Deceleration time
constant
(parameter No. 14)
Setting range 0 to 100ms
Analog monitor 1 (MO1) output selection
(Signal output to across MO1-LG)
Analog monitor 2 (MO2) output selection
(Signal output to across MO2-LG)
Description
5 - 21
Tb Ts
Tb
Setting range [mV]
999 to 999