Detailed Description Of Signals (Devices); Forward Rotation Start Reverse Rotation Start Temporary Stop/Restart - Mitsubishi Electric MR-J2S-CP Instruction Manual

Melservo j2-super series
Table of Contents

Advertisement

3. SIGNALS AND WIRING

3.4 Detailed description of signals (devices)

3.4.1 Forward rotation start Reverse rotation start Temporary stop/restart

(1) A forward rotation start (ST1) or a reverse rotation start (ST2) should make the sequence which can
be used after the main circuit has been established. These signals are invalid if it is switched on before
the main circuit is established.
Normally, it is interlocked with the ready signal (RD).
(2) A start in the servo amplifier is made when the external start signal changes from OFF to ON. The
delay time of the servo amplifier's internal processing is max. 3ms. The delay time of other signals is
max. 10ms.
(3) When a programmable controller is used, the ON time of the start/stop signal should be 5ms or longer
to prevent a malfunction.
(4) During operation, the forward rotation start (ST1) or reverse rotation start (ST2) is not accepted. The
next operation should always be started after the rough match (CPO) is output with the rough match
output range set to 0 or after the movement finish (MEND) is output.
Servo motor speed
Forward rotation start (ST1)
or reverse rotation start (ST2)
Temporary stop/Restart (STP)
3ms or less
3ms or less
10ms
or less
5ms or more
3 - 13