Alarm Status Display

The maintainer can display current system alarm levels for the entire system or for separate
categories. The categories are
Lines
Trunks
DTMF receivers
PCM channels.

Configuration Report

The configuration report allows the maintainer to display the system configuration showing the
location of major devices down to the level of the modules installed on cards in the peripheral
bays.

Copy Database

The maintainer can make a backup copy of the system database onto a storage medium on a
PC.

Customer Data Entry (CDE) Backup and Restore

This feature allows customer data to be dumped onto a storage medium on a PC, and also
allows new generic software to be loaded into the system from a PC.

Device Error Analysis Statistics

The SX-200 EL and the SX-200 ML systems record errors detected during the operation of
datasets, HDLC links, and T1 trunks. Maintenance personnel can generate statistical reports
based on this data.

Device Status Report

The maintainer can display the status of any peripheral circuit or circuits by entering a command
at the maintenance terminal. The information displayed includes: circuit location, circuit type,
call processing state and maintenance state.

Diagnostics

The SX-200 EL and SX-200 ML systems have a comprehensive diagnostic package. The
diagnostics test the operation of the system hardware. The main control system controls and
schedules the diagnostics.
There are three types of diagnostic routines:
Power-up