Mitel SX-2000 EL Information Manual page 237

Microprocessor-controlled telephone system
Table of Contents

Advertisement

Assumptions made for this example of receiver requirements
-
CLASS hold time = 4.51 seconds average for incoming traffic
-
For ACD applications the 100% of total traffic is assumed for the incoming traffic
-
For heavy traffic conditions p.999 is recommended.
LS/CLASS
Circuits
4
8
12
16
20
24
28
32
36
40
44
48
Note: Shaded configurations exceed number of system allowable receivers (5)
50003510
CLASS Receiver Requirements for Heavy Traffic
Incoming
Total Calls
Percentage
per hour
of total
traffic
50
35%
50
100%
99
35%
99
100%
144
35%
144
100%
251
33%
251
100%
360
31%
360
100%
478
31%
478
100%
594
30%
594
100%
730
29%
730
100%
829
29%
829
100%
962
28%
962
100%
1095
28%
1095
100%
1226
28%
1226
100%
CLASS rcvr
Traffic Load
Erlangs
0.02
0.06
0.04
0.12
0.06
0.18
0.10
0.31
0.14
0.45
0.19
0.60
0.22
0.74
0.27
0.91
0.30
1.04
0.34
1.21
0.38
1.37
0.43
1.54
Revision A
Specifications
Required CLASS
receivers for ERLANG B
Grade of Service
P.99
P.999
2
2
2
3
2
2
2
3
2
3
3
3
2
3
3
4
2
3
3
5
3
3
4
5
3
4
4
5
3
4
5
6
3
4
5
6
3
4
5
7
3
4
6
7
3
4
6
7
223

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sx-2000 ml

Table of Contents