1.3.2 Option Interface

The followings are the Serial Interface Specifications by Type-B 32-K
serial interface.
o Interface type:
RC232C or CURRENT LOOP
o Data transmission system: Full Duplex
o Synchronism:
n Synchronous:
Asynchronous
n Start bit:
1BIt
n Stop bit:
1Bit (Other bits could be used, but without
guaranty of proper operation)
n Data bit:
7Bit or 8Bit (DP-SW 1-2)
n Parity:
None Even, Odd (DP-SW 1-3, 1-4)
n Protocol:
- X-ON/X-OFF (Can not be used with DTR control) (DP-SW 2-3)
- DTR Control (Can not be used with X-ON/X-OFF) (DP-SW 2-3)
n Transmission rates:
300, 600, 1200, 1800, 2400, 4800, 9600, 19200 baud