13. Connect a power cable to the back of the drive. The connectors are keyed and
14. If you have other options to install or remove, do so now.
15. Replace the cover. See "Replacing the cover" on page 56 for details.
16. Reconnect the external cables and power cords; then turn on the attached
Power and signal cables for internal drives: The computer uses cables to connect
IDE devices to the power supply and to the system board. The following cables are
provided:
v Four-wire power cables connect the drives to the power supply. At the end of
v Flat signal cables, also called ribbon cables, connect IDE and diskette drives to
Review the following information before connecting power and signal cables to
internal drives:
v The drives that are preinstalled in the computer come with power and signal
v When you install a drive, ensure that the drive connector at the end of the signal
v If two IDE devices are used on a single cable, one must be designated as the
54
Hardware Maintenance Manual: IBM IntelliStation E Pro Type 6204 and Type 6214
Note: Make sure to route the signal cable so that it does not block the air flow
to the rear of the drives or over the microprocessor.
can be inserted only one way.
devices and the computer.
these cables are plastic connectors that attach to different drives; these
connectors vary in size. Also, certain power cables attach to the system board.
the system board. There are two sizes of ribbon cables that come with the
computer.
– The wider IDE signal cable has two or three connectors.
- If the cable has three connectors, one of these connectors is attached to the
drive, one is a spare, and the third attaches to the primary or secondary
IDE connector on the system board.
- If the cable has two connectors, one of these connectors is attached to the
hard disk drive, and the other attaches to the primary or secondary IDE
connector on the system board.
Note: The CD-ROM drive will have an ATA 66 signal cable. ATA 66 signal
cables are color-coded. The blue connector attaches to the system
board. The black connector attaches to the primary device. The gray
middle connector attaches to the secondary device. If you are installing
a hard disk drive, you must change the switch setting on the CD-ROM
drive to secondary and change the connector used for the CD-ROM
drive to the gray middle connector.
– The narrower signal cable has two connectors, one to attach to the diskette
drive, and the other to attach to the connector (FDD1) on the system board.
To locate connectors on the system board, see "System board internal cable
connectors" on page 44.
cables attached. If you replace any drives, it is important to remember which
cable is attached to which drive.
cable is always connected to a drive, and ensure that the drive connector at the
other end is connected to the system board. This reduces electronic noise from
the computer.
primary device and the other as the secondary device; otherwise, the computer
might not detect some of the IDE devices. The primary and secondary
designation is determined by switch or jumper settings on each IDE device.