Table 3. NetWare driver messages for the Ethernet controller (continued)
Message
Duplicate slot numbers detected.
'xxx' is not supported for AFT
team.
Primary and Secondary adapters
do not match. AFT group is not
created.
Requested number of Secondary
cards are not found.
Failed to create AFT group. Make
sure that the drivers for supported
adapters are loaded, primary
adapter is bound to protocols, and
secondary adapter is not bound to
any protocols.
Error identifying slot numbers for
the specified board names.
Can't unbind specified slot from
AFT group. Make sure that the slot
you specified is for the primary
adapter in an AFT group.
LAN adapter at slot nnnn (Port
0xaa) failed to reset. Check the
state of the adapter.
AFT is not supported on this
version of NetWare.
Description
Explanation: An attempt has been made to bind the same slot number more
than once.
Action: Check the slot numbers entered during the bind. Adapter slot numbers
must be valid and unique. If the problem persists, contact the network
administrator.
Explanation: A bind command has been issued for adapters not supported by
AFT.NLM.
Action: Make sure that you attempt to bind only adapters supported by
AFT.NLM.
Explanation: A bind command was entered for an adapter team that is a
combination of computer and client adapters. An AFT team must be a
grouping of the same classification of adapter.
Action: Verify that all the adapters bound in a team are of the same
classification.
Explanation: The number of adapters specified in the bind command could not
be located.
Action: Verify the numbers and slot locations of the adapters to be bound. If
the problem persists, contact the network administrator.
Explanation: Binding of protocol failed. Protocol is either not bound to any
adapter or is bound to more than one adapter in the group.
Action: Ensure that the protocol is bound to only one adapter in an AFT team.
Explanation: The mapping between the board name entered and the slot
number for an adapter could not be established.
Action: Check the board name for the adapter before issuing the bind
command. If the problem persists, contact the network administrator
Explanation: The number entered in the unbind command was not the
primary adapter in an AFT group.
Action: Reissue the unbind command and specify the slot number for the
primary adapter
Explanation: The adapter that you specified could not be initialized.
Action:
1. Load the driver for the supported adapter.
2. Check that the adapter is seated properly in the slot and try loading the
AFT module again.
If the problem persists, contact the network administrator.
Explanation: The NetWare on your computer is not a version supported by
AFT.
Action: Load and bind AFT only on supported versions of NetWare (currently
version 4.11 and above).