IBM 621410U - IntelliStation E - Pro 6214 Hardware Maintenance Manual page 124

Hardware maintenance manual
Table of Contents

Advertisement

Error Code/Symptom
602 (Invalid diskette boot
record)
604 (Diskette drive error)
662 (Diskette drive
configuration error)
962 (Parallel port error)
11XX (System board serial
port 1 or 2 error)
1162 (Serial port
configuration conflict)
1200 (microprocessor machine
check)
1762 (Configuration change
has occurred)
1780 (Hard disk error)
1781 (Hard disk error)
1782 (Hard disk error)
1783 (Hard disk error)
1800
(No more hardware interrupt
available for PCI adapter)
116
Hardware Maintenance Manual: IBM IntelliStation E Pro Type 6204 and Type 6214
FRU/Action
1. Diskette
2. Diskette Drive
3. Cable
4. System Board
1. Run Configuration/Setup and Diagnostics
2. Diskette Drive
3. Drive Cable
4. System Board
1. Run Configuration/Setup and Diagnostics
2. Diskette Drive
3. Drive Cable
4. System Board
1. Disconnect external cable on parallel port.
2. Run Configuration/Setup
3. System Board
1. Disconnect external cable on serial port.
2. Run Configuration/Setup
3. System Board
1. Disconnect external cable on serial port
2. Run Configuration/Setup
3. System board
1. Microprocessor
1. Run Configuration/Setup
1. Run Configuration/Setup
2. Hard disk drive
3. Hard disk drive cable
1. Run Configuration/Setup
2. Hard disk drive
3. Hard disk drive cable
1. Run Configuration/Setup
2. Hard disk drive
3. Hard disk drive cable
1. Run Configuration/Setup
2. Hard disk drive
3. Hard disk drive cable
1. Run Configuration/Setup
2. Failing Adapter
3. System Board

Advertisement