IBM 621410U - IntelliStation E - Pro 6214 Hardware Maintenance Manual page 118

Hardware maintenance manual
Table of Contents

Advertisement

Error Code/Symptom
015-XXX-015
(Failed USB External
Loopback test)
015-XXX-198
(USB device connected
during USB test)
020-XXX-000
(Failed PCI Interface test)
030-XXX-000
(Failed Internal SCSI interface
test)
030-XXX-00N
(Failed SCSI test on PCI slot
N. Check system error log
before replacing a FRU.)
035-XXX-099
035-XXX-S99
(Failed RAID test on PCI slot
S. S = number of failing PCI
slot. Check System Error Log
before replacing a FRU.)
035-XXX-SNN
(Check System Error Log
before replacing a FRU. S =
number of failing PCI slot;
NN = SCSI ID of failing fixed
disk.)
035-253-S99
(RAID adapter initialization
failure)
075-XXX-000
(Failed Power Supply test)
089-XXX-001
(Failed Microprocessor test)
180-XXX-003
(Failed System Board LED
test)
110
Hardware Maintenance Manual: IBM IntelliStation E Pro Type 6204 and Type 6214
FRU/Action
1. Make sure parallel port is not disabled
2. Re-run USB External Loopback test
3. System Board
1. Remove USB devices from USB1 and USB2
2. Re-run test
3. System Board
1. System Board
1. System Board
1. Adapter in Slot N
1. No adapters were found.
2. If adapter is installed re-check connection.
1. Adapter
2. SCSI Backplane
3. Cable
1. Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S.
1. ServeRAID Adapter in slot S is not configured properly. Obtain the basic and
extended configuration status and refer to the ServeRAID Hardware Maintenance
Manual for more information.
2. Cable
3. Adapter
1. Power Supply
1. Microprocessor
1. System Board

Advertisement

Table of Contents
loading

This manual is also suitable for:

Intellistation e pro 6214

Table of Contents