Konica Minolta bizhub PRESS C6000 User Manual page 238

Ic-601 color centro user guide
Hide thumbs Also See for bizhub PRESS C6000:
Table of Contents

Advertisement

13.7
Improve the Accuracy of the Profile Set
[Measurement] screen appears.
3
From [Instrument], select the instrument to use for the measurement.
According to the selection, the chart image appears on the upper-right of the screen.
% [i11Sis (UV Filer)] returns the measurement result with the UV cut filter.
4
Specify the copy number of the chart outputting to [Copies].
5
Click [Output] to print the chart.
6
Click [Start] to start the measurement.
% According to the selected instrument, the operation screen appears. Follow the instructions on the
pages that follow.
% The current position of measurement appears on the chart image of the upper-right of the screen.
% If you measure a wrong line, a warning message appears. You can select either to try again with the
correct line or to proceed to the next line.
% For detailed information on how to operate, refer to user's guide of each instrument.
% To stop the measurement, click [Stop].
% After the acquirement of measurement data, [Save the Result] becomes available.
% The value of each patch appears in the measurement result list.
7
Click [Save the Result] after completing the measurement.
[Save As] screen appears.
8
Specify the saving place and file name, and click [Save].
[Measurement] screen returns after saving the measurement result file.
9
Click [OK].
[Feedback] screen returns.
On [Feedback] screen, the measurement data is displayed.
10
Click [Execute Feedback].
Profile is calculated.
After completing calculation, [Measurement] screen appears.
11
Repeat from Step 4 to Step 9.
IC-601
13
13-36