Konica Minolta bizhub PRESS C6000 Safety Information Manual

Konica Minolta bizhub PRESS C6000 Safety Information Manual

Bizhub press c6000/c7000 safety information guide
Hide thumbs Also See for bizhub PRESS C6000:

Advertisement

Advertisement

Table of Contents
loading

Summary of Contents for Konica Minolta bizhub PRESS C6000

  • Page 2: Table Of Contents

    Contents Introduction Welcome ............................1-2 1.1.1 Composition of User's Guide......................1-2 Energy Star® ........................... 1-4 Legal Restrictions on Copying....................... 1-5 Precautions for Installation and Use Safety Information........................... 2-2 2.1.1 Disassemble and Modification......................2-3 2.1.2 Power Cord ............................2-3 2.1.3 Power Source ............................ 2-3 2.1.4 Power Plug............................
  • Page 3 MEMO contents-2 bizhub PRESS C7000/C6000...
  • Page 4: Introduction

    Introduction...
  • Page 5: Welcome

    Welcome Introduction Welcome Thank you for purchasing this machine. This User's Guide describes the functions, operating instructions, precautions for correct operation, and sim- ple troubleshooting guidelines of this machine. In order to obtain maximum performance from this product and use it effectively, please read this User's Guide as necessary. 1.1.1 Composition of User's Guide Printed manuals...
  • Page 6 Welcome User's guide CD manuals Overview [User's Guide - Network Scanner (IC-601)] This guide describes the operation of network scan- ner functions using IC-601. • Scan to E-mail • Scan to HDD • Scan to FTP • Scan to SMB [User's Guide - Security] This guide describes the security functions.
  • Page 7: Energy Star

    Energy Star® ® Energy Star The ENERGY STAR® Program has been established to encourage the wide- spread and voluntary use of energy efficient technologies that reduce energy consumption and prevent pollution. As an ENERGY STAR Partner, we have determined that this product meets the ENERGY STAR guidelines for energy efficiency, based on the following features.
  • Page 8: Legal Restrictions On Copying

    Legal Restrictions on Copying Legal Restrictions on Copying Certain types of original must never be copied with the purpose or intent to pass copies of such documents off as the originals. The following is not a complete list, but is meant to be used as a guide to responsible copying. Financial Instruments Personal checks Traveler’s checks...
  • Page 9 Legal Restrictions on Copying MEMO bizhub PRESS C7000/C6000...
  • Page 10: Precautions For Installation And Use

    Precautions for Installation and Use...
  • Page 11: Safety Information

    Safety Information Precautions for Installation and Use Safety Information This section contains detailed instructions on the operation and maintenance of this machine. To achieve op- timum utility of this device, all operators should carefully read and follow the instructions in this manual. Please read the following section before connecting the machine to the supply.
  • Page 12: Disassemble And Modification

    Safety Information 2.1.1 Disassemble and Modification Do not attempt to remove the covers and panels which have been fixed to the product. Some products have a high-volt- age part or a laser beam source inside that could cause an electrical shock or blindness. Do not modify this product, as a fire, electrical shock, or breakdown could result.
  • Page 13: Power Plug

    Safety Information 2.1.4 Power Plug Do not unplug and plug in the power cord with a wet hand, as an electrical shock could result. Plug the power cord all the way into the power outlet. Failure to do this could result in a fire or electrical shock. Do not tug the power cord when unplugging.
  • Page 14: Ventilation

    Safety Information 2.1.7 Ventilation Using this product in a poorly ventilated room for a long time or producing a large volume of copies or prints may cause the odor of exhaust air from the machine. Ventilate the room well. 2.1.8 Actions in Response to Troubles Do not keep using this product, if this product becomes inor- dinately hot or emits smoke, or unusual odour or noise.
  • Page 15: When Moving The Machine

    Safety Information 2.1.10 When Moving the Machine Whenever moving this product, be sure to disconnect the power cord and other cables. Failure to do this could damage the cord or cable, resulting in a fire, electrical shock, or breakdown. Do not move this product. If it is moved or falls, it may cause severe personal injury.
  • Page 16: Perfect Binder

    Safety Information 2.1.15 Perfect Binder Do not use the perfect binder without ventilation for an ex- tended period of time. Ensure to ventilate the room on a reg- ular basis. It is recommended that the perfect binder should be installed in a place with a local exhaust system. Using the perfect binder in a room without appropriate ventilation could pose health hazard.
  • Page 17: Regulation Notices

    Regulation Notices Regulation Notices 2.2.1 Laser Safety This product employs a Class 3B laser diode having maximum power of 15 mW and wavelength of 785-800 This product is certified as a Class 1 laser product. Since the laser beam is concealed by protective housings, the product does not emit hazardous laser radiation as long as the product is operated according to the in- structions in this manual.
  • Page 18: Ozone Release

    Regulation Notices - For Denmark Users ADVARSEL Usynlig laserstråling ved åbning, når sikkerhedsafbrydere er ude af funktion. Undgå udsættelse for sråling. Klasse 1 laser produkt der opfylder IEC 60825-1 sikkerheds kravene. Dansk: Dette er en halvlederlaser. Laserdiodens højeste styrke er 15 mW og bølgelængden er 785-800 nm. - For Norway Users ADVARSEL Dersom apparatet brukes på...
  • Page 19 Regulation Notices This perchlorate warning applies to perchlorate-containing lithium batteries sold or distributed in California, USA. "Perchlorate Material - Special handling may apply, See www.dtsc.ca.gov/ hazardouswaste/perchlorate." CE Marking (Declaration of Conformity) for Users of the European Union (EU) This product complies with the following EU directives: 2004/108/EC and 2006/95/EC directives.
  • Page 20: Warning And Caution Labels

    Warning and Caution Labels Warning and Caution Labels This machine has warning label, caution labels and indicators for safety precaution in the following location. These labels and indicators advise you to pay special attention to avoid any dangerous situations or serious injury when you replace the units.
  • Page 21: Caution Label On Fixing Conveyance Unit

    Warning and Caution Labels 2.3.2 Caution Label on Fixing Conveyance Unit 7 CAUTION DO NOT put your hand or arm between the main body and the fixing conveyance unit. Touching connecting terminals of electric parts may damage the machine or cause unexpected trouble. Please do not try to work yourself, but contact your service representative.
  • Page 22: Caution Label On Toner Recovery Box

    Warning and Caution Labels 2.3.4 Caution Label on Toner Recovery Box 7 WARNING NEVER throw the toner recovery box into a fire. Otherwise, the toner may ignite and cause a dangerous situation. bizhub PRESS C7000/C6000 2-13...
  • Page 23: Caution Label On Perfect Binder Pb-503

    Warning and Caution Labels 2.3.5 Caution Label on Perfect Binder PB-503 7 CAUTION DO NOT touch the paste tank unit. Otherwise, you may get burned. Please be especially careful if you push the paste tank unit backward in place. 2-14 bizhub PRESS C7000/C6000...
  • Page 24: Caution Label On Finisher Fs-531/Finisher Fs-612

    Warning and Caution Labels 2.3.6 Caution Label on Finisher FS-531/Finisher FS-612 7 CAUTION DO NOT put your hand on the top of printed sheets when removing them from the primary (main) tray. Failure to do so may cause unexpected injury, such as getting your fingers squeezed between the main body and the primary (main) tray going upward.
  • Page 25: Caution Label On Large Capacity Unit Lu-202

    Warning and Caution Labels 2.3.7 Caution Label on Large Capacity Unit LU-202 7 CAUTION DO NOT put your hand into the three holes on the tray bottom plate. Failure to do so may cause unexpected injury, such as getting your hand squeezed. Be especially care- ful when loading paper.
  • Page 26: Caution Labels On Multi Punch Gp-501

    Warning and Caution Labels 2.3.8 Caution Labels on Multi Punch GP-501 7 WARNING This safety message means you could get an electrical shock because disconnecting power from this section does not cut off power from adjacent sections of the machine. 7 WARNING This safety message means that you might get seriously hurt or killed if you open the product and ex- pose yourself to hazardous voltage.
  • Page 27: Installation Space

    Installation Space Installation Space Allow sufficient space for facilitating copy operation, changing parts, and periodic inspection. Leave an ad- equate space behind the machine to let hot air out from the rear fan. The whole machine may weigh approx. 1,407 kg (3,101.85 lb) at maximum, depending on the combination of options.
  • Page 28 Installation Space (unit: mm) (unit: mm) 1639 1639 1478 1478 1041 1041 2143 2143 RU-509 - Main body (+ IC-413/IC-601 + HD-514) - PF-602 SD-506 - RU-509 - Main body (+ IC-413/IC-601 + HD-514) - PF-602 (unit: mm) 1639 1231 1020 Total width (except Image Controller IC-306/IC-307) 3,100 : FD-503 - (RU-509 - Main body - PF-602)
  • Page 29 Installation Space (unit: mm) 1639 1020 Total width (except Image Controller IC-306/IC-307) 3,886 : LS-505 x 2 - (RU-509 - Main body - PF-602) 3,658 : LS-505 x 2 - (RU-509 - Main body - LU-202) 3,200 : LS-505 x 2 - (RU-509 - Main body) (unit: mm) 1639 1020...
  • Page 30 Installation Space (unit: mm) 1639 1223 1020 1360 Total width (except Image Controller IC-306/IC-307) 3,676 : PB-503 - (RU-509 - Main body - PF-602) 3,448 : PB-503 - (RU-509 - Main body - LU-202) 2,990 : PB-503 - (RU-509 - Main body) (unit: mm) 1639 1020...
  • Page 31 Installation Space (unit: mm) 1639 1020 Total width (except Image Controller IC-306/IC-307) 3,631 : FS-521 - FD-503 - (RU-509 - Main body - PF-602) 3,403 : FS-521 - FD-503 - (RU-509 - Main body - LU-202) 2,945 : FS-521 - FD-503 - (RU-509 - Main body) 4,246 : FS-521 - FD-503 - (RU-506 - GP-501 - RU-509 - Main body - PF-602) 4,018 : FS-521 - FD-503 - (RU-506 - GP-501 - RU-509 - Main body - LU-202) (unit: mm)
  • Page 32 Installation Space (unit: mm) 1639 1223 1020 1360 Total width (except Image Controller IC-306/IC-307) 4,861 : PB-503 - LS-505 - FD-503 - (RU-509 - Main body - PF-602) 4,633 : PB-503 - LS-505 - FD-503 - (RU-509 - Main body - LU-202) 4,175 : PB-503 - LS-505 - FD-503 - (RU-509 - Main body) (unit: mm) 1639...
  • Page 33 Installation Space (unit: mm) 1639 1020 1360 1170 Total width (except Image Controller IC-306/IC-307) 6,161 : FS-521 - PB-503 - SD-506 - FD-503 - (RU-509 - Main body - PF-602) 5,933 : FS-521 - PB-503 - SD-506 - FD-503 - (RU-509 - Main body - LU-202) 5,475 : FS-521 - PB-503 - SD-506 - FD-503 - (RU-509 - Main body) (unit: mm) 1639...
  • Page 34 Installation Space (unit: mm) 1639 1020 Total width (except Image Controller IC-306/IC-307) 4,016 : FS-521 - LS-505 - (RU-509 - Main body - PF-602) 3,788 : FS-521 - LS-505 - (RU-509 - Main body - LU-202) 3,330 : FS-521 - LS-505 - (RU-509 - Main body) 4,631 : FS-521 - LS-505 - (RU-506 - GP-501 - RU-509 - Main body - PF-602) 4,403 : FS-521 - LS-505 - (RU-506 - GP-501 - RU-509 - Main body - LU-202) (unit: mm)
  • Page 35 Installation Space (unit: mm) 1639 1223 1020 1360 1170 Total width (except Image Controller IC-306/IC-307) 5,631 : PB-503 - SD-506 - LS-505 - (RU-509 - Main body - PF-602) 5,403 : PB-503 - SD-506 - LS-505 - (RU-509 - Main body - LU-202) 4,945 : PB-503 - SD-506 - LS-505 - (RU-509 - Main body) (unit: mm) 1639...
  • Page 36 Installation Space (unit: mm) 1639 1020 Total width (except Image Controller IC-306/IC-307) 4,801 : FS-521 - LS-505 x 2 - (RU-509 - Main body - PF-602) 4,573 : FS-521 - LS-505 x 2 - (RU-509 - Main body - LU-202) 4,115 : FS-521 - LS-505 x 2 - (RU-509 - Main body) (unit: mm) 1639...
  • Page 37 Installation Space (unit: mm) 1639 1223 1020 1360 1170 Total width (except Image Controller IC-306/IC-307) 4,846 : PB-503 - SD-506 - (RU-509 - Main body - PF-602) 4,618 : PB-503 - SD-506 - (RU-509 - Main body - LU-202) 4,160 : PB-503 - SD-506 - (RU-509 - Main body) (unit: mm) 1639 1020...
  • Page 38 Installation Space (unit: mm) 1639 1130 250.5 Total width (except Image Controller IC-306/IC-307) 3,106.5 : FS-612 - PI-502 - (RU-509 - Main body - PF-602) 2,878.5 : FS-612 - PI-502 - (RU-509 - Main body - LU-202) 2,420.5 : FS-612 - PI-502 - (RU-509 - Main body) 2,010.5 : FS-612 - PI-502 - (Main body) 2,696.5 : FS-612 - PI-502 - (Main body - PF-602) 2,468.5 : FS-612 - PI-502 - (Main body - LU-202)
  • Page 39 Installation Space (unit: mm) 1639 1130 250.5 Total width (except Image Controller IC-306/IC-307) 3,106.5 : FS-531 - PI-502 - (RU-509 - Main body - PF-602) 2,878.5 : FS-531 - PI-502 - (RU-509 - Main body - LU-202) 2,420.5 : FS-531 - PI-502 - (RU-509 - Main body) 2,010.5 : FS-531 - PI-502 - (Main body) 2,696.5 : FS-531 - PI-502 - (Main body - PF-602) 2,468.5 : FS-531 - PI-502 - (Main body - LU-202)
  • Page 40: Operation Precautions

    Operation Precautions Operation Precautions To ensure the optimum performance of this machine, observe the precautions described below. 2.5.1 Power source The power source requirements are as follows. Destination North America Europe, Southeast Asia, Australia Voltage 208 V to 240 V AC 220 V to 240 V AC Frequency 60 Hz...
  • Page 41: Precaution For Use Of Folding Unit And Finisher

    Operation Precautions 2.5.6 Precaution for use of Folding Unit and Finisher The primary (main) tray of Folding Unit FD-503, Finisher FS-521, Finisher FS-531, or of Finisher FS-612 gradually goes down while printed materials output. DO NOT allow any object to interfere with the operation of the tray on the left side of the staple finisher, as any interference may cause damage to the staple finisher.

This manual is also suitable for:

Bizhub press c7000/c7000pBizhub press c7000

Table of Contents